EWI Substrate Pull-Off Test Log Template
Download Printable PDF Test Log
Enter your work email to receive the high resolution printable substrate pull off test recording log.
Printable Substrate Test Recording Table
Log minimum 3 test points per distinct elevation. Minimum acceptable tensile adhesion is typically 0.08 N/mm2 (80 kN/m2) cohesive failure.
| Test # | Elevation | Substrate Type | Primer Used | Adhesive | Peak Load (kN) | Tensile (N/mm2) | Failure Mode | Result |
|---|---|---|---|---|---|---|---|---|
| T-01 | Front / East | Existing pebble dash render over concrete block | Acrylic deep primer | System bonding mortar | 0.32 kN | 0.16 N/mm2 | Cohesive within substrate (100% block fracture) | PASS |
| T-02 | Rear / West | Painted sand cement smooth render | Silicate adhesion key primer | System bonding mortar | 0.24 kN | 0.12 N/mm2 | Cohesive failure of existing paint layer | PASS |
| T-03 | Gable / North | Direct concrete masonry blockwork | Water misted | System bonding mortar | 0.45 kN | 0.23 N/mm2 | Cohesive failure within blockwork matrix | PASS |
Failure Mode Definitions
Cohesive: Fracture occurs inside the masonry block or adhesive layer. Indicates excellent bond strength.
Adhesive: Separation occurs cleanly at the interface. May indicate contamination or need for primer.
Minimum Tensile Thresholds
ETAG 004 and EAD 040083 guidelines require a minimum tensile adhesion strength of 0.08 N/mm2 (80 kN/m2) between adhesive and substrate under dry laboratory conditions.
Apparatus Calibration
Pull off test apparatus must carry an active calibration certificate (within 12 months). Record the equipment serial number and calibration date on every project sheet.
Log Tensile Tests Directly in CertFile
The CertFile mobile app calculates N/mm2 values automatically, captures load gauge photos with GPS tags, and compiles pull off test certificates into your 10 year NSAI audit folder.